Paste 700h

Paste 700

Under Tile Waterproofing and Anti Fracture Membrane

Paste 700® is designed to waterproof surfaces which will have tile, brick, slate, pavers or other similar finished surfaces installed directly over the substrate. AVM 700 may also be used to waterproof shower pans, counter-tops, or other areas in continuously wet environments. AVM Paste 700 is certified to meet ANSI A118.10 Specifications.

ICC ESR-2662ICC PMG-2662

SYSTEM COMPONENTS

Paste 700 5 gallon bucket

Paste 700

3.5 & 5 Gal Bucket

Under tile waterproofing and anti fracture membrane

Primer 100 5 gallon bucket primer

Primer 100

2 & 5 Gal Bucket

Suitable for wood, concrete and sheet metel substrates

Mat 800 three size variants reinforcement mats

Mat 800

6”x81’ | 40”x81’ | 40”x324 6”x100yrd | 12”x100yrd

Reinforcement mat for use with multiple AVM systems

OPTIONAL PROTECTIVE COATING

Aggregate 400 50lbs Bag - Polymer Modified Cement for Sloping, Leveling and Patching

Aggregate 400

50lb | Grey or White

For use in sloping and brown coats

Additive 7400 3 and 5 gallon bucket

Additive 7400

2 & 5 Gal Bucket

Heavy duty, multi-purpose additive

AVM Placeholder Logo

Additive 7700

Fluid Applied Waterproofing

Multi Purpose Acrylic Concrete Additive

GALLERY

GALLERY

MATERIAL CALCULATOR  

  • How many square feet is your job?

  • SYSTEM COMPONENTS
  • WHAT YOU NEED
  • AVM Primer 100

  • Gallons
  • AVM Paste 700

  • Gallons
  • AVM Mat 800

  • Rolls
  • OPTIONAL PROTECTIVE COATING
  • AVM Aggregate 200

  • Bags
  • AVM Concrete Additive 7400

  • Gallons
  • WANT TO SAVE A COPY?

Refer to page 2 of “Specifications Sheet” (in pdf) for available packaging sizes
This is an estimating tool only. Actual quantities needed may vary by job conditions and other factors.
Additional components/materials not listed here might be needed.
For additional guidance, contact our sales staff at 818-888-0050
AVM reserves the right to change any information on this document at any time witout notice.

ARCHITECTURAL DETAILS

SYSTEM 700 – WATER BASED ACRYLIC

EXTERIOR

0700-0750-0000-Exterior-Quick-View-All(PDF)
0700-0750-0002-C-Tile-Assembly-Roof-or-Deck-Double-Membrane-CS-TXR(PDF)(DWG)
0700-0750-0042-C-Tile-Assembly-Roof-or-Deck-Single-Membrane-CS(PDF)(DWG)
0700-0750-0102-C-Tile-Assembly-Balcony-or-Deck-Single-Membrane-CS-TXR(PDF)(DWG)
0700-0750-0502-C-Tile-Assembly-over-Slab-on-Grade-Basic-CS-TXR(PDF)(DWG)
0700-0750-0602-C-Tile-Assembly-over-Slab-on-Grade-with-Mortar-Bed-CS-TXR(PDF)(DWG)
0700-0750-1002-WF-Tile-Assembly-Roof-or-Deck-Double-Membrane-CS-TXR(PDF)(DWG)
0700-0750-1102-WF-Tile-Assembly-Roof-or-Deck-Single-Membrane-over-Mortar-Bed-Thin-Set-CS(PDF)(DWG)
0700-0750-1104-WF-Terminations-Thin-Set-Tile-Assembly-Roof-or-Deck-Single-Membrane-over-Mortar-Bed-Thin-Set-CS(PDF)(DWG)
0700-0750-1112-WF-Tile-Assembly-Roof-or-Deck-Single-Membrane-over-Mortar-Bed-Thick-Set-CS(PDF)(DWG)
0700-0750-1502-C-Tile-Assembly-Exterior-Concrete-or-Masonry-Wall-CS-TXR(PDF)(DWG)
0700-0750-1552-C-Tile-Assembly-Exterior-Concrete-or-Masonry-Wall-and-Mortar-Bed-CS-TXR(PDF)(DWG)
0700-0750-1702-WF-Tile-Assembly-Exterior-Wall-Wood-Frame-Metal-Stud-Backer-Board-CS-TXR(PDF)(DWG)
0700-0750-2202-WF-Tile-Assembly-Exterior-Wood-Stairs-Membrane-Under-Mortar-Bed-CS-TXR(PDF)(DWG)
0700-0750-2204-Double-System-Pool-Shell-CS-TXR(PDF)(DWG)

INTERIOR BATHS SHOWERS

0700-0750-0000-Interior-Bath-Quick-View-All(PDF)
0700-0750-0000-Interior-Floor-Quick-View-All2(PDF)
0700-0750-3002-WF-Tile-Bath-Shower-Walls-Prefab Receptor-Mortar-Bed-CS-TXR(PDF)(DWG)
0700-0750-3004-WF-Tile-Bath-Shower-Walls-Prefab Receptor-Backer-Board-CS-TXR(PDF)(DWG)
0700-0750-3006-WF-Tile-Bath-Shower-Walls-AVM-Detail-3004-Enlarged-CS-TXR(PDF)(DWG)
0700-0750-3008-WF-Tile-Bath-Shower-Walls-Prefab Receptor-Coated-Glass-Mat-Gypsum-Board-CS-TXR(PDF)(DWG)
0700-0750-3010-WF-Tile-Bath-Shower-Walls-Prefab Receptor-Fiber-Reinforced-Gypsum-Board-CS-TXR(PDF)(DWG)
0700-0750-3102-WF-Tile-Shower-Receptors-Wood-Metal-Studs-Cement-Backer-Board-Walls-Mortar-Bed-Floor-CS-TXR(PDF)(DWG)
0700-0750-3104-WF-Tile-Shower-Receptors-Wood-Metal-Studs-Fiber-Cement-Backer-Board-Walls-Mortar-Bed-Floor-CS-TXR(PDF)(DWG)
0700-0750-3106-WF-Tile-Shower-Receptors-Wood-Metal-Studs-Coated-Glass-Mat-Gypsum-Board-Walls-Mortar-Bed-Floor-CS-TXR(PDF)(DWG)
0700-0750-3108-WF-Tile-Shower-Receptors-Wood-Metal-Studs-Fiber-Reinforced-Gypsum-Board-Walls-Mortar-Bed-Floor-CS-TXR(PDF)(DWG)
0700-0750-3110-WF-Tile-Shower-Receptors-Wood-Metal-Studs-Cement-Coated-Extruded-Foam-Backer-Board-Walls-Mortar-Bed-Floor-CS-TXR(DWG)
0700-0750-3112-WF-Tile-Shower-Receptors-Solid-Backing-Bonded-Waterproof-Membrane-CS-TXR(PDF)(DWG)
0700-0750-3114-WF-Tile-Shower-Receptors-Solid-Backing-Bonded-Waterproof-Membrane-Drain-Flange-CS-TXR(PDF)(DWG)
0700-0750-3502-WF-Tile-Tubs-Fountains-Curbs-Waterproof-Membrane-Wood-Only-Forms-CS-TXR(PDF)(DWG)
0700-0750-3504-WF-Tile-Tubs-Fountains-Curbs-Waterproof-Membrane-Concrete-Wood-Curbs-CS-TXR(PDF)(DWG)
0700-0750-3532-WF-Tile-Tubs-Fountains-Curbs-Waterproof-Membrane-Preformed-Curbs-CS-TXR(PDF)(DWG)
0700-0750-3902-C-Tile-Tubs-Fountains-Pools-Concrete-Tank-Mortar-Bed-over-Membrane-CS-TXR(PDF)(DWG)
0700-0750-3922-C-Tile-Assembly-in-Pool-or-Pond-Concrete-Tank-Bonded-Mortar-Bed-CS-TXR(PDF)(DWG)
0700-0750-4002-C-Tile-Steam-Shower-Room-Concrete-Masonry-CS-TXR(PDF)(DWG)
0700-0750-4004-C-Tile-Steam-Shower-Room-Concrete-Masonry-AVM-Detail-4002-Enlarged-CS-TXR(PDF)(DWG)
0700-0750-4202-WF-Tile-Steam-Shower-Room-Wood-Frame-CS-TXR(PDF)(DWG)
0700-0750-4204-WF-Tile-Steam-Shower-Room-Wood-Frame-AVM-Detail-4202-Enlarged-CS-TXR(PDF)(DWG)
0700-0750-4502-C-Tile-Radiant-Heat-Over-Concrete-CS-TXR(PDF)(DWG)
0700-0750-4504-C-Tile-Radiant-Heat-Over-Concrete-CS-TXR(PDF)(DWG)
0700-0750-4506-C-Tile-Radiant-Heat-Over-Concrete-CS-TXR(PDF)(DWG)
0700-0750-4508-C-Tile-Radiant-Heat-Over-Concrete-CS-TXR(PDF)(DWG)
0700-0750-4510-C-Tile-Radiant-Heat-Over-Concrete-CS-TXR(PDF)(DWG)
0700-0750-4702-WF-Tile-Radiant-Heat-Over-Wood-Frame-CS-TXR(PDF)(DWG)
0700-0750-4704-WF-Tile-Radiant-Heat-Over-Wood-Frame-CS-TXR(PDF)(DWG)
0700-0750-4706-WF-Tile-Radiant-Heat-Over-Wood-Frame-CS-TXR(PDF)(DWG)
0700-0750-4732-WF-Tile-Radiant-Heat-Over-Wood-Frame-CS-TXR(PDF)(DWG)

INTERIOR FLOOR WALL

0700-0750-0000-Interior-Floor-Quick-View-All(PDF)
0700-0750-0000-Interior-Floor-Quick-View-All2(PDF)
0700-0750-5002-C-Tile-Assembly-over-Slab-on-Grade-CS-TXR(PDF)(DWG)
0700-0750-5022-C-Tile-Assembly-over-Slab-on-Grade-over-Self-Leveling-Underlayment-CS-TXR(PDF)(DWG)
0700-0750-5042-C-Tile-Assembly-over-Slab-on-Grade-over-Gypsum-Underlayment-CS-TXR(PDF)(DWG)
0700-0750-5202-C-Tile-Assembly-over-Slab-on-Grade-or-Elevated-Slab-over-Unbonded-Mortar-Bed-CS-TXR(PDF)(DWG)
0700-0750-5212-C-Tile-Assembly-over-Slab-on-Grade-or-Elevated-Slab-over-Bonded-Mortar-Bed-CS-TXR(PDF)(DWG)
0700-0750-5302-C-Tile-Assembly-over-Elevated-Slab-CS-TXR(PDF)(DWG)
0700-0750-5322-C-Tile-Assembly-over-Elevated-Slab-over-Gypsum-Underlayment-CS-TXR(PDF)(DWG)
0700-0750-5502-WF-Tile-Assembly-over-Plywood-Subfloor-Joists-16-Inch-OC-over-Wire-Reinforced-Unbonded-Mortar-Bed-CS-TXR(DWG)
0700-0750-5542-WF-Tile-Assembly-over-Plywood-Subfloor-Joists-16-Inch-OC-over-Lath-Reinforced-Mortar-Bed-CS-TXR(PDF)(DWG)
0700-0750-5582-WF-Tile-Assembly-over-Plywood-Subfloor-Joists-16-Inch-OC-over-Cement-Backer Board-CS-TXR(PDF)(DWG)
0700-0750-5622-WF-Tile-Assembly-over-Plywood-Subfloor-Joists-16-Inch-OC-over-Coated-Glass-Mat-Water-Resistant-Gypsum-Backer Board-CS-TXR(DWG)
0700-0750-5642-WF-Tile-Assembly-over-Plywood-Subfloor-Joists-24-Inch-OC-over-Coated-Glass-Mat-Water-Resistant-Gypsum-Backer Board-CS-TXR(DWG)
0700-0750-5662-WF-Tile-Assembly-over-Plywood-Subfloor-Joists-16-Inch-OC-over-Coated-Glass-Mat-Water-Resistant-Gypsum-Backer Board-CS-TXR(DWG)
0700-0750-5702-WF-Tile-Assembly-over-Plywood-Subfloor-Joists-16-Inch-OC-over-Poured-Gypsum-Underlayment-CS-TXR(PDF)(DWG)
0700-0750-5752-WF-Tile-Assembly-over-Plywood-Subfloor-Joists-19-Inch-OC-over-Cementitious-Self-Leveling-Underlayment-CS-TXR(DWG)
0700-0750-5782-WF-Tile-Assembly-over-Plywood-Subfloor-Joists-16-Inch-OC-over-Plywood-Underlayment-CS-TXR(PDF)(DWG)
0700-0750-5802-WF-Tile-Assembly-over-Plywood-Subfloor-Joists-24-Inch-OC-over-Plywood-Underlayment-CS-TXR(PDF)(DWG)
0700-0750-6002-C-Tile-Assembly-Interior Walls-over-Solid-Backing-Mortar-Bed-CS-TXR(PDF)(DWG)
0700-0750-6004-C-Tile-Assembly-Interior Walls-over-Solid-Backing-Mortar-Bed-One-Coat-Method-CS-TXR(PDF)(DWG)
0700-0750-6102-WF-Tile-Assembly-Interior Walls-over-Wood-or-Metal-Studs-over-Mortar-Bed-CS-TXR(PDF)(DWG)
0700-0750-6162-C-Tile-Assembly-Interior Walls-over-Wood-or-Metal-Studs-over-Cement-Backer-Board-CS-TXR(PDF)(DWG)
0700-0750-6182-C-Tile-Assembly-Interior Walls-over-Wood-or-Metal-Studs-over-Fiber-Reinforced-Water-Resistant-Gypsum-Backer-Board-CS-TXR(DWG)
0700-0750-6302-C-Tile-Assembly-Interior Walls-over-Masonry-or-Concrete-CS-TXR(PDF)(DWG)
0700-0750-6322-C-Tile-Assembly-Interior Walls-over-Wood-or-Metal-Studs-over-Bonded-Mortar-Bed-CS-TXR(PDF)(DWG)
0700-0750-7002-C-Tile-Assembly-in-Pool-or-Pond-Concrete-Tank-Bonded-Mortar-Bed-CS-TXR(PDF)
0700-0750-7502-C-Tile-Assembly-Interior-Floors-Crack-Isolation-Membrane-Full-Coverage-CS(PDF)(DWG)
0700-0750-7552-C-Tile-Assembly-Interior-Floors-Crack-Isolation-Membrane-Partial-Coverage-CS-TXR(PDF)(DWG)