Got a Question?

Request More Info on the Aussie Clay 590

Contact Us
Aussie Clay 590h

Aussie Clay 590

Bentonite Composite Sheet Waterproofing Membrane

The AVM Aussie Clay is a heavy-duty high strength Bentonite Composite Sheet Waterproofing Membrane consisting of needle punched woven and non-woven geotextile fabrics encapsulating a thick layer of active sodium bentonite between them. AVM Aussie Clay is designed for below-grade vertical and horizontal structural foundation surfaces. Aussie Clay may be applied vertically to permanent formwork such as lagging or other property line construction or to existing back-filled structural walls. Aussie Clay may also be applied horizontally either to smoothly prepared concrete substrates and/or compacted earth or crushed stone substrates. Aussie Clay may also be used in conjunction with the AVM Aussie Skin membrane as part of a “Dual Membrane” Assembly.

ICC ESR-5397LARR REPORT

System Components

Aussie Clay PL Aussie Skin Roll 590

Aussie Clay PL

Bentonite Clay Waterproofing Membrane with Poly Liner

AVM Placeholder Logo

Aussie Clay SW

Salt / Contaminated Water Bentonite Clay Waterproofing Membrane

Aussie Clay SW PL Aussie Skin Roll 590

Aussie Clay SW PL

Salt / Contaminated Water Bentonite Clay Waterproofing Membrane with Poly Liner

AVM Placeholder Logo

Aussie Clay Granules

Pure Sodium Bentonite Granules

Aussie Clay Sealant aussie clay sealant

Aussie Clay Sealant

Trowel-grade sodium bentonite-butyl Rubber Sealant

Optional Components

Tie Back Cover 4″ Tie Back Cover 4

Tie Back Cover 4″

Tie Back Cover 4"

Heavy Duty Plastic

Tie Back Cover 6″ Tie Back Cover 6

Tie Back Cover 6″

Tie Back Cover 6"

Heavy Duty Plastic

Tie Back Cover 8″ Tie Back Cover 8

Tie Back Cover 8″

Tie Back Cover 8"

Heavy Duty Plastic

GALLERY

ARCHITECTURAL DETAILS

SYSTEM 590 – AUSSIE CLAY

BACKFILLED

0590 – Backfilled – View-ALL (PDF)
0590.0002 – CIP, NH – Backfilled Wall 01 (PDF)(DWG)
0590.0003 – CIP, NH – Backfilled Wall 02 (PDF)(DWG)
0590.0102A – CIP, NH – Typical Backfilled Wall 01 (PDF)(DWG)
0590.0102B – CIP, NH – Typical Backfilled Wall 02 (PDF)(DWG)
0590.0103 – CIP, NH – Typical Backfilled Wall 03 (PDF)(DWG)
0590.0205 – CIP, NH – Backfilled Wall – Pipe Penetration (PDF)(DWG)
0590.0207 – CIP, NH – Backfilled Wall – Sleeved Pipe Penetration (PDF)(DWG)
0590.0302 – CIP, NH – Backfilled Wall – Grade Termination 01 (PDF)(DWG)
0590.0304 – CIP, NH – Backfilled Wall – Grade Termination 02 (PDF)(DWG)
0590.0306 – CIP, NH – Backfilled Wall – Brick Ledge Termination 01 (PDF)(DWG)
0590.0308 – CIP, NH – Backfilled Wall – Brick Ledge Termination 02a (PDF)(DWG)

BLIND SIDE

0590 – Blind Side – View-ALL (PDF)
0590.0001A – Under Slab Assembly – Single System (PDF) (DWG)
0590.0001B – Under Slab Assembly – Dual Layer (PDF) (DWG)
0590.0010 – CIP – Blind Side Waterproofing over Metal Sheet Piling (PDF) (DWG)
0590.0012 – SC – Blind Side Waterproofing over Metal Sheet Piling 02 (PDF) (DWG)
0590.0100 – CIP – Blind Side Waterproofing Over Lagging (PDF) (DWG)
0590.0101 – CIP,SC, H,NH – Blind Side Waterproofing Over Lagging (PDF) (DWG)
0590.0110 – CIP, NH – Blind Side Waterproofing Over Lagging, US Drainage (PDF) (DWG)
0590.0112 – NH,SC – Blind Side Waterproofing Over Lagging, US Drainage (PDF) (DWG)
0590.0200 – CIP – Pipe Penetration (PDF) (DWG)
0590.0202 – SC – Pipe Penetration (PDF) (DWG)
0590.0206 – CIP – Sleeved Pipe Penetration (PDF) (DWG)
0590.0208 – SC – Sleeved Pipe Penetration (PDF) (DWG)
0590.0210 – Slab Penetration Over Mud Slab (PDF) (DWG)
0590.0215 – Slab Penetration Over Compacted Earth (PDF) (DWG)
0590.0220 – SC – Typical Soldier Pile (PDF) (DWG)
0590.0222 – CIP – Typical Soldier Pile (PDF) (DWG)
0590.0223 – CIP – Back Lagged Soldier Pile (PDF) (DWG)
0590.0224 – SC – Back Lagged Soldier Pile (PDF) (DWG)
0590.0225 – SC – Metal Tie-Back Cover (PDF) (DWG)
0590.0230 – CIP – Metal Tie-Back Cover (PDF) (DWG)
0590.0235 – SC – Tie-Back Cover (PDF) (DWG)
0590.0236 – CIP – Tie-Back Cover (PDF) (DWG)

ARCHITECTURAL DETAILS

SYSTEM 550 – AUSSIE SKIN

BIM, REVIT

0550-0002 SLAB ON GRADE OVER AUSSIE SKIN CONCRETE WALLS (RVT)
0550-0004 SLAB ON GRADE OVER AUSSIE SKIN CMU BLOCK WALLS (RVT)
0550-0006 SLAB ON GRADE OVER AUSSIE SKIN CONCRETE WALLS MINIMAL EXPOSED FOOTING (RVT)
0550-0008 ELEVATED SLAB OVER AUSSIE SKIN CONCRETE WALLS (RVT)
0550-0010 ELEVATED SLAB OVER AUSSIE SKIN CMU BLOCK WALLS (RVT)
0550-0023 AUSSIE SKIN PIPE BANK PITCH PAN (DWG)
0550-1510 BLIND SIDE WATERPROOFING OVER LAGGING SINGLE SYSTEM ABOVE WATER TABLE (RVT)
0550-1520 BLIND SIDE WATERPROOFING OVER LAGGING DUAL SYSTEM BELOW WATER TABLE (RVT)
0550-2500 GRADE BEAM DETAIL AUSSIE SKIN UNDER GRADE BEAM (RVT)
0550-2540 GRADE BEAM DETAIL AUSSIE SKIN OVER GRADE-BEAM (RVT)
0550-2600 PILE CAP DETAIL (RVT)
0550-6010 NAIL SCREW DETAIL (RVT)
0550-6200 INSIDE CORNER DETAIL (RVT)